The cavity wall real performance question
[edit] Introduction
Can the actual heat loss from a newly constructed property be greater than you calculated or realised? This question was asked in the early part of 2021 by the owner of a recently built property that became surprisingly cold during, and following, heavy storms. He had never considered to what extent wet masonry can increase heat loss from the building.
Heat loss calculations take all of this into account – or do they? Calculations of the thermal behaviour of cavity walls are not based on using water saturated bricks. Calculations are based on dry bricks or minimally wet bricks, with a water content of 5% maximum. This is fine when one considers performance during summer months, but not so in winter, when one relies most on conserving heat. As an outside skin becomes wetter, its conductivity increases and its thermal integrity worsens.
However, the situation deteriorates further because of evaporative cooling (EC). EC affects humans and buildings. When we swim in the sea and then emerge from the water, the body feels cold and becomes colder because of EC. The air is causing the water on your skin to evaporate, and that draws heat from your body.
Buildings have skins too, and a buildings’ wet outside skin will also suffer EC, accelerating heat loss from the structure. Unlike your body, where the water lays on your skin surface, the brick outer skin of a building can be saturated with water, so EC can really accelerate the thermal loss.
It is also worth remembering how some masonry is tested to BS 4315. The test involves spraying water onto a given area at a rate of 2.5 litres per minute. The test takes place over 48 hours. Upon completion of the test, it is not unusual to read ‘the bricks indicated very low levels of rates of rain penetration.’ It is often not realised the spraying is not continuous. It lasts just one minute, followed by a half-hour pause, after which there is another one minute of spraying and so on. Over 48 hours, the extent of water spraying amounts to less than 1½ hours. If it only ever rains in your district for exactly one minute followed always by half an hours’ drying time, then perhaps BS 4315 is meaningful, albeit not a realistic representation of the climate experienced in the UK (especially when one remembers wet winter days with accompanying high winds…and EC). As a realist might point out, the conductivity of a clay brick can double when it is saturated.
[edit] Two considerations
Two simple considerations can help minimise overall thermal loss through a cavity wall. The first requires appropriate cavity tray specification to manage water arrestment and water evacuation. The more swiftly and efficiently the external skin returns to dry status the better, and with it, acceleration of thermal loss diminishes.
Awarded European Technical Approval (ETA) for its water arrestment protective products, Cavity Trays Ltd of Yeovil is the only UK cavity tray manufacturer awarded ETA and offers construction overviews and a take-off service. The company also manufactures a wide range of wall weeps and vents, so elevations can benefit tray-compatible balanced cavity ventilation and water removal.
The second consideration refers to a cavity wall reveal closer that does what no other reveal closer offers. Called a Continuity Closer, it features an L-shaped insulating core. Being L-shaped instead of the conventional rectangular shape permits it to wrap across the surface of partial-fill cavity insulation, and in so doing, it over-sails/covers those gaps that are often witnessed on sites where ordinary closers and cavity insulation are meant to abut – but don’t. The Continuity Closer physically layers those gaps that would otherwise be left and adversely increase heat loss.
Building envelope performance is reliant on many build details coming together, and the two simple examples demonstrate how improvement is readily available and readily achievable.
This article originally appeared in the Architectural Technology Journal (at) issue 140 published by CIAT in winter 2021. It was written by John Shillabeer, Chair, Cavity Trays Ltd.
--CIAT
[edit] Related articles on Designing Buildings
Featured articles and news
An engaging and lively review of his professional life.
Sustainable heating for listed buildings
A problem that needs to be approached intelligently.
50th Golden anniversary ECA Edmundson apprentice award
Deadline for entries has been extended to Friday 27 June, so don't miss out!
CIAT at the London Festival of Architecture
Designing for Everyone: Breaking Barriers in Inclusive Architecture.
Mixed reactions to apprenticeship and skills reform 2025
A 'welcome shift' for some and a 'backwards step' for others.
Licensing construction in the UK
As the latest report and proposal to licence builders reaches Parliament.
Building Safety Alliance golden thread guidance
Extensive excel checklist of information with guidance document freely accessible.
Fair Payment Code and other payment initiatives
For fair and late payments, need to work together to add value.
Pre-planning delivery programmes and delay penalties
Proposed for housebuilders in government reform: Speeding Up Build Out.
High street health: converting a building for healthcare uses
The benefits of health centres acting as new anchor sites in the high street.
The Remarkable Pinwill Sisters: from ‘lady woodcarvers’ to professionals. Book review.
Skills gap and investment returns on apprenticeships
ECA welcomes new reports from JTL Training and The Electrotechnical Skills Partnership.
Committee report criticises UK retrofit schemes
CIOB responds to UK’s Energy Security and Net Zero Committee report.
Design and construction industry podcasts
Professional development, practice, the pandemic, platforms and podcasts. Have we missed anything?
C20 Society; Buildings at Risk List 2025
10 more buildings published with updates on the past decade of buildings featured.
Boiler Upgrade Scheme and certifications consultation
Summary of government consultation, closing 11 June 2025.
Deputy editor of AT, Tim Fraser, discusses the newly formed society with its current chair, Chris Halligan MCIAT.